Products and ServicesEngineering Technical Service SeriesIntelligent Potential Collector
Intelligent Potential Collector
The Intelligent Potential Collector is a dedicated remote monitoring terminal for cathodic protection systems. It integrates high-precision signal acquisition, ultra-low power consumption control, wireless transmission and long-term power supply modules. The device can automatically collect core parameters including pipeline on/off potentials, AC and DC currents, and battery remaining capacity. Data is uploaded to the cloud platform via dual communication (4G + Bluetooth), enabling unattended remote monitoring and intelligent early warning of cathodic protection conditions. It is applicable to various cathodic protection projects such as long-distance oil & gas transmission pipelines, urban pipe networks and tank farms.
Core Features
-
Multi-parameter Precision AcquisitionSynchronously acquire on/off potentials and native potential, AC and DC currents, and battery remaining capacity, featuring high data accuracy and comprehensive coverage.
Multi-parameter Precision Acquisition -
Wireless Remote MonitoringRemote data upload via 4G plus on-site commissioning through Bluetooth; support real-time data viewing and remote parameter configuration.
Wireless Remote Monitoring -
Intelligent Early Warning & DiagnosisAutomatic alarm upon abnormal data, intelligent system analysis and rapid fault location.
Intelligent Early Warning & Diagnosis
Features
-
Ultra-Low Power Consumption & Long Service LifeTimed wake-up and automatic sleep are supported. The device can operate independently on a single long-life battery for no less than 5 years, with a design life of 10 years.
-
Industrial-Grade ProtectionIP67 protection rating, magnesium-aluminum alloy housing, waterproof, dustproof and moisture-proof. Suitable for harsh buried and outdoor working conditions.
-
Strong Anti-Interference StabilityHigh input impedance, immunity to AC and DC interference, stable data acquisition under severe stray current environments.
Product Technical Parameters
| No. | Function Item | Parameter Name | Parameter Value |
|---|---|---|---|
| 1 | On-Potential Sampling | Sampling Range | ±30V |
| Sampling Error | <±10mV@3V,≤1%@30V | ||
| Number of Detectable Channels | 2 Channels | ||
| 2 | Off-Potential Sampling | Sampling Range | ±3V |
| Sampling Error | <±10mV | ||
| Number of Detectable Channels | 1 Channels | ||
| 3 | Native Potential Sampling | Sampling Range | ±3V |
| Sampling Error | <±10mV | ||
| Number of Detectable Channels | 1 Channels | ||
| 4 | AC Voltage Sampling | Sampling Range | 0V~100V(RMS) |
| Sampling Error | ≤1% | ||
| Number of Detectable Channels | 1 Channels | ||
| 5 | AC Coupon Current Sampling | Sampling Range | 100mA |
| Sampling Error | ≤1% | ||
| Sampling Resistance | 1Ω | ||
| 6 | Polarization Coupon Current Sampling | Sampling Range | ±20mA |
| Sampling Error | ≤1% | ||
| Sampling Resistance | 1Ω | ||
| 7 | Battery Remaining Capacity Sampling | Sampling Range | 0%~100% |
| Sampling Error | <±1% | ||
| 8 | Current through Reference Electrode | Current Limit | <3μA |
| 9 | Reference Input Impedance | Impedance Limit | >10MΩ |
Swipe Left or Right to View the Full Table
Product Certification
Compliant with standards including SY/T 0017 and GB/T 3482. Certified by petroleum industry electrical testing and lightning protection testing institutions, suitable for industrial-grade applications in the oil and gas industry.
Construction Instructions
1. Installation Positioning: Fix on pipeline test post or designated position, implement waterproof wiring.
2. Wiring & Sampling: Connect reference electrode, test coupon and cables; provide insulation protection for terminals.
3. Bluetooth Configuration: Establish Bluetooth connection via APP, set sampling interval and alarm threshold.
4. Network Commissioning: Test 4G signal and verify data upload.
5. Enclosure Sealing Protection: Waterproof sealing, suitable for buried or outdoor installation.
Related Cases
-